Privacy Policy

Effective Date: September 29, 2026

Information We Collect

We collect information you provide directly to us, such as when you create an account, make a purchase, contact us for support, or sign up for our newsletter.

How We Use Your Information

We use the information we collect to:

  • Provide, maintain, and improve our services
  • Process transactions and send related information
  • Send technical notices, updates, and security alerts
  • Respond to your comments, questions, and customer service requests
  • Communicate with you about products, services, and events

Information Sharing and Disclosure

We do not sell, trade, or otherwise transfer your personal information to third parties without your consent, except as described in this policy or as required by law.

Cookies and Tracking Technologies

We use cookies and similar tracking technologies to collect and track information about your use of our website. You can control cookie preferences through our cookie consent banner.

Data Security

We implement appropriate security measures to protect your personal information against unauthorized access, alteration, disclosure, or destruction.

Your Rights and Choices

You have the right to:

  • Access and review your personal information
  • Correct inaccurate information
  • Request deletion of your information
  • Object to processing of your information
  • Withdraw consent for data processing

Third-Party Services

Our website may contain links to third-party websites or services. We are not responsible for the privacy practices of these third parties.

Children's Privacy

Our services are not intended for children under 13 years of age. We do not knowingly collect personal information from children under 13.

Changes to This Policy

We may update this privacy policy from time to time. We will notify you of any changes by posting the new policy on this page with an updated effective date.

Contact Information

If you have any questions about this Privacy Policy, please contact us at:

Email: privacy@pottorff.com
Phone: (555) 123-4567
Address: 123 Main Street, City, State 12345

Rep Login (817) 509-2300 Send Us A Message
a banner, everything is blue, a flying plane above a truck

Quick Ship Program

Pottorff offers exceptional standard delivery times as well as several Quick Ship Options. Please see below for available quantities, sizes, options and accessories.

24 Hour 3-Day 7-Day

Category Product Location Maximum Qty Minimum Charge Options and Accessories
24hr 3-Day 7-Day 24hr 3-Day 7-Day
Fire Dampers VFD-10, VFD-30 TX, CA 50* 100* 200* 40% 25% 15% Retaining angles. Net OD dimensions. Varying fuse link temps. Horizontal and vertical applications.
VFD-10, VFD-30 TX, CA 25* 50* 100* 40% 25% 15% 16, 18 & 20 GA. A, B or C sleeves. Round, flanged and DM-35 duct transition. Stainless Steel. Retaining angles. Net OD dimensions. Varying fuse link temps, sleeve lengths and clearances. Horizontal and vertical applications.
VFD-10-IS, VFD-30-IS TX, CA 50* 100* 200* 40% 25% 15% 20 GA. A, or B sleeves. Round, flanged and DM-35 duct transitions. Retaining angles. Net OD dimensions. Varying fuse link temps, sleeve lengths and clearances. Horizontal and vertical applications.
VFD-10-TL, VFD-10D-TL TX, CA 5* 5* 15* 40% 25% 15% 16, 18 & 20 GA. A, or B sleeves. Round, flanged and DM-35 duct transitions. Retaining angles, Net OD dimensions. Varying fuse link temps, sleeve lengths and clearances. Horizontal and vertical applications.
VFD-10-IM TX, CA 50 100 200 40% 25% 15% 20 GA. A, or B sleeves. Round, flanged and DM-35 duct transitions. Retaining angles. Net OD dimensions. Varying fuse link temps, sleeve lengths and clearances. Horizontal and vertical applications.
VFD-10D TX, CA 50* 100* 200* - 25% 15% 4000 fpm, 16, 18 & 20 GA. A or B sleeves. Round, flanged and DM-35 duct transitions. Stainless steel. Retaining angles. Net OD dimensions. Varying fuse link temps, sleeve lengths and clearances. Horizontal and vertical applications.
VFD-10D TX, CA - 100* 200* - 25% 15% 4000 fpm, 16, 18 & 20 GA. A, B or C sleeves. Round, flanged and DM-35 duct transitions. Stainless steel. Retaining angles. Net OD dimensions. Varying fuse link temps, sleeve lengths and clearances. Horizontal and vertical applications.
VFD-30D TX, CA 50* 100* 200* 40% 25% 15% 4000 fpm, 16, 18 & 20 GA. A or B sleeves. Round, flanged and DM-35 duct transitions. Stainless steel. Retaining angles. Net OD dimensions. Varying fuse link temps, sleeve lengths and clearances. Horizontal and vertical applications.
VFD-15R, VFD-35R CA 5 10 25 40% 25% 15% 16 & 20 GA. sleeves. Varying fuse link temps, sleeve lengths and clearances. Horizontal and vertical applications.
VFD-15R-IS, VFD-35R-IS CA 5 10 25 40% 25% 15% 20 GA. sleeves. Varying fuse link temps, sleeve lengths and clearances. Horizontal and vertical applications.
FD-125R CA 15 20 30 40% 25% 15% Varying fuse link temps.
FD-140 (OP), FD-150 (OP), FD-340 TX, CA 15* 20* 30* 40% 25% 15% 16, 18 & 20 GA. sleeves. Round, flanged and DM-35 duct transitions. Horizontal and vertical applications.
Smoke & Fire/Smoke Dampers FSD-141, 142, 143, (OP), (SP) TX, CA 15* 20* 30* 40% 25% 15% Side plate. 16, 18 & 20 GA. sleeves. No sleeves. Round, flanged and DM-35 duct transitions. Stainless steel. Retaining angles. Net OD dimensions. Stock actuators. PI-50. Duct mounted smoke detector (3-day, maximum of 5 units or 7-day only) and loose smoke detector. Varying fuse link temps, sleeve lengths and clearances. DRS-30, RCP-1, RCP-1K, RCP-1M and RCP-1M-NL.
FSD-151, 152, (OP), (SP) CA
FSD-171 (OP), FSD-172 (OP) TX, CA 15 20 30 40% 25% 15% 16, 18 & 20 GA. sleeves. Round, flanged and DM-35 duct transitions. Stainless steel. Stock actuators. PI-50. Duct mounted smoke detector (3-day, maximum of 5 units or 7-day only) and loose smoke detector. DRS-30, RCP-1, RCP-1K, RCP-1M and RCP-1M-NL.
FSD-341, 342, 351, 352 TX, CA 15* 20* 30* 40% 25% 15% Side plate. 16, 18 & 20 GA. sleeves. No sleeves. Round, flanged and DM-35 duct transitions. Retaining angles. Net OD dimensions. Stock actuators. PI-50. Duct mounted smoke detector (3-day, maximum of 5 units or 7-day only) and loose smoke detector. Varying fuse link temps, sleeve lengths and clearances. DRS-30, RCP-1, RCP-1K, RCP-1M and RCP-1M-NL.
FSD-125R CA 15 20 30 40% 25% 15% Varying fuse link temps. Stock actuators. DRS-30, Horizontal mount, RCP-1, RCP-1K, RCP-1M and RCP-1M-NL.
SD-141, 142 TX, CA 15 20 30 40% 25% 15% Retaining angles. Net OD dimensions. Stock actuators. PI-50. Duct mounted smoke detector (3-day, maximum of 5 units or 7-day only) and loose smoke detector. Varying sleeve lengths and clearances. DRS-30, RCP-1, RCP-1K, RCP-1M and RCP-1M-NL.
SD-151, 152 CA
SD-25R CA 15 20 30 40% 25% 15% Stock actuators. RCP-1, RCP-1K, RCP-1M and RCP-1M-NL
Ceiling Radiation Dampers CFD-15R TX, CA 50 100 200 40% 25% 15% CRB-24, WHI-20.
CFD-15R TX, CA 25 50 100 40% 25% 15% 22 GA sleeves. VC-165, CRB-24, WHI-20. Varying sleeve lengths.
CFD-15 (No Round Transitions) TX, CA 50 100 200 40% 25% 15% 22 GA. sleeves. Flange transition. VC-165, CRB-24, WHI-20. All plaster ground connections. Varying sleeve lengths.
CFD-15 (With Round Transitions) TX, CA - 20 50 - 25% 15%
CFD-521 (NP) TX 50 100 200 40% 25% 15% Round transitions (mounted or loose). VC-165, WHI-20. All plaster ground connections. Boot rails.
CFD-521-IP TX 50 100 200 40% 25% 15% VC-165, WHI-20. All plaster ground connections. Boot rails. Round transitions (mounted or loose).
CFD-521-90 TX - 100 200 - 25% 15%
CFD-521-BT TX 25 50 100 40% 25% 15% R-8.0. VC-165. Boot rails. Does not apply to 45° option.
CFD-20 TX, CA 30 60 120 40% 25% 15% 22 GA sleeves. Round duct transitions. CRB-24, WHI-20. All plaster ground connections. Varying sleeve lengths.
Air Control Dampers CD-10R CA 30 80 200 40% 25% 15% 22 GA. Sleeves. Standoff. Stainless steel. Varying sleeve lengths and clearances. Locking quadrants.
CD-10 CA 30 60 120 40% 25% 15% 22 GA. Sleeves. Standoff. Locking quadrants.
CD-21R CA 30 60 150 40% 25% 15% Low leakage seals. Stock actuators. Stainless steel. Varying sleeve lengths. Standoff brackets.
CD-25R CA 30 60 150 40% 25% 15% Low leakage seals. Stock actuators. Stainless steel. Varying sleeve lengths. Locking quadrants. Standoff brackets.
CD-41, 42, 45, 46 TX, CA 15* 45* 60* 40% 25% 15% Low leakage seals. Locking quadrants. Stock actuators. 16, 18 and 20 GA. Sleeves. Round. Flanged. DM-35 duct transitions. Stainless steel. Side plates. Net OD dimensions. Varying sleeve lengths and clearances. Standoff. Vertical blades. Stainless steel bushings. PI-50.
CD-51, 52 TX, CA - 20* 50* - 25% 15% Low leakage seals. Locking quadrants. Stock actuators. 16, 18 and 20 GA. Sleeves. Round. Flanged. DM-35 duct transitions. Side plates. New OD dimensions. Varying sleeve lengths and clearances. Standoff. Vertical blades. Stainless steel bushings. PI-50.
MD-41, 42 TX, CA 15* 45* 60* 40% 25% 15% Standoff. Locking quadrant. Net OD dimensions. No top/bottom stops. Stainless steel bushings.
Backdraft Dampers BD-20R (catalog sizes only) TX, CA - - 100 - - 15%
BD-150, 250 TX 30* 60* 120* 40% 25% 15% B (Discharge) or C (Intake) mounting flange. Net OD dimensions.
BD-150, 250 (with sleeves and/or Stock actuators) TX - 10* 20* - 25% 15% B (Discharge) or C (Intake) mounting flange. New OD dimensions. Varying sleeve lengths and clearances. 16, 18 and 20 GA. Stock actuators.
CBD-150, 250 TX 30* 60* 120* 40% 25% 15% B (Discharge) or C (Intake) mounting flange. New OD dimensions. Vertical or horizontal. Airflow up mount.
CBD-150, 250 (with sleeves) TX - 10* 20* - 25% 15% B (Discharge) or C (Intake) mounting flange. New OD dimensions. Varying sleeve lengths and clearances. 16, 18 and 20 GA. Stock actuators.
BD-51 TX 10* 20* 60* 40% 25% 15% B or C mounting flange. New OD dimensions. Varying sleeve lengths and clearances. 16, 18 and 20 GA.
Louvers (Standard paint extends the Quick Ship Program by 2 days) SFD-445/635, SFJ-445/645 CA - 5* 10* - 25% 15% Integral flange frame (mechanically fastened only). Standard head and sill flashing. New OD dimensions. Clip and continuous angles. No screen. Insect screen - aluminum (18-16 mesh).
ECD-245/445/545/635
EDD-445/637
EFD-245/435/437/445/637/645
EFJ 430/437/445, EFK-430/437/445
EFJ-437-HP, EFJ-637-HP
TX ≤50 sq. ft. ≤175 sq. ft. ≤250 sq. ft. 40% 25% 15% Integral flange frame (mechanically fastened only). Standard head and sill flashing. Net OD dimensions. Clip and continuous angles. Screen location - front/exterior. No screen. Insect screen - aluminum (18-14 mesh). Insect screen - aluminum (18-16 mesh). Bird screen - galvanized (1/2” x 19 GA). Insect screen - stainless steel (18-16 mesh). Florida Building Code construction. Custom flange (n/a for 24 hour). Stucco and glazing frame - match louver. Frame only - match louver. Filter rack. Blankoff. Burglar bars.
EFJ-937-MD, EXA-645-MD TX - - ≤50 sq. ft. - - 15%
EFY-245/445, EFJ-245/645
EFK-637/645
TX ≤25 sq. ft. ≤100 sq. ft. ≤150 sq. ft. 40% 25% 15%
EFD-637-MD TX ≤25 sq. ft. ≤50 sq. ft. ≤100 sq. ft. 40% 25% 15% Integral flange frame (mechanically fastened only). Standard head and sill flashing. Net OD dimensions. Clip and continuous angles. Sleeved (n/a for 24 hour). Screen location - Front/exterior. No screen. Insect Screen - aluminum (18-14 mesh). Insect screen - aluminum (18-16 mesh). Bird screen - galvanized (1/2” x 19 GA.). Insect screen - stainless steel (18-16 mesh). Florida Building Code construction. Custom flanges (n/a for 24 hour). Stucco and glazing frame. Screen and frame - match louver. Frame only - match louver. Filter rack. Blankoff. Burglar bars.
ECD-545-MD TX - - ≤100 sq. ft. - - 15% Integral flange frame (mechanically fastened only). Standard head and sill flashing. Net OD dimensions. Clip and continuous angles. Sleeved. Screen location - Front/exterior. No screen. Insect Screen - aluminum (18-14 mesh). Insect screen - aluminum (18-16 mesh). Bird screen - galvanized (1/2” x 19 GA.) Insect screen - stainless steel (18-16 mesh). Custom flanges (n/a for 24 hour). Stucco and glazing frame. Screen and frame - match louver. Frame only - match louver. Filter rack. Blankoff. Burglar bars.
EEI-430, EFE-430-HP TX - ≤25 sq. ft. ≤50 sq. ft. - 25% 15% Integral flange frame (mechanically fastened only). Standard head and sill flashing. Net OD dimensions. Clip and continuous angles. Screen location - Front/exterior. No screen. Insect Screen - aluminum (18-14 mesh). Insect screen - aluminum (18-16 mesh). Bird screen - galvanized (1/2” x 19 GA.) Insect screen - stainless steel (18-16 mesh). Custom flanges (n/a for 24 hour). Stucco and glazing frame. Screen and frame - match louver. Frame only - match louver. Filter rack. Blankoff. Burglar bars.
ECD-745 TX - ≤25 sq. ft. ≤50 sq. ft. - 25% 15% Standard head and sill flashing. Net OD dimensions. Clip and continuous angles. Screen location - Front/exterior. No screen. Insect Screen - aluminum (18-14 mesh). Insect screen - aluminum (18-16 mesh). Bird screen - galvanized (1/2” x 19 GA.). Insect screen - stainless steel (18-16 mesh). Custom flanges (n/a for 24 hour). Stucco and glazing frame. Screen and frame - match louver. Frame only - match louver. Filter rack. Blankoff. Burglar bars.
EBE-445, EBI-445 TX - ≤25 sq. ft. ≤50 sq. ft. - 25% 15% Integral flange frame (mechanically fastened only). Standard head and sill flashing. Net OD dimensions. Clip and continuous angles. Screen location - Front/exterior. No screen. Insect Screen - aluminum (18-14 mesh). Insect screen - aluminum (18-16 mesh). Bird screen - galvanized (1/2” x 19 GA.) Insect screen - stainless steel (18-16 mesh). Custom flanges (n/a for 24 hour). Stucco and glazing frame. Screen and frame - match louver. Frame only - match louver. Filter rack. Blankoff. Burglar bars.
EOD-445/637, EOJ-445/637
EXD-437/645, EXA-645
TX - ≤25 sq. ft. ≤50 sq. ft. - 25% 15% Stock actuators. Integral flange frame (mechanically fastened only). Standard head and sill flashing. Net OD dimensions. Clip and continuous angles. Jamb and blade seals. Screen location - Front/exterior. No screen. Insect screen - aluminum (18-14 mesh). Insect screen - aluminum (18-16 mesh). Bird screen - galvanized (1/2” x 19 GA.) Insect screen - stainless steel (18-16 mesh). Custom flanges (n/a for 24 hour). Stucco and glazing frame. Screen and frame - match louver. Frame only - match louver. Filter rack. Blankoff. Burglar bars.
EBV-145/445 (Catalog sizes only) TX - 50 150 - 25% 15%
Access Doors HAD, CAD (Catalog sizes only) CA, TX 10 25 100 40% 25% 15% Standard latch quantities.
DM, DMR (Catalog sizes only) CA, TX - 20 40 - 25% 15%
DMHT-2300 (Catalog sizes only) CA, TX - 5 10 - 25% 15%

Fire Dampers

VFD-10, VFD-30

TX, CA
24hr
50*
Min. charge 40%
3-Day
100*
Min. charge 25%
7-Day
200*
Min. charge 15%
Retaining angles. Net OD dimensions. Varying fuse link temps. Horizontal and vertical applications.

VFD-10, VFD-30

TX, CA
24hr
25*
Min. charge 40%
3-Day
50*
Min. charge 25%
7-Day
100*
Min. charge 15%
16, 18 & 20 GA. A, B or C sleeves. Round, flanged and DM-35 duct transition. Stainless Steel. Retaining angles. Net OD dimensions. Varying fuse link temps, sleeve lengths and clearances. Horizontal and vertical applications.

VFD-10-IS, VFD-30-IS

TX, CA
24hr
50*
Min. charge 40%
3-Day
100*
Min. charge 25%
7-Day
200*
Min. charge 15%
20 GA. A, or B sleeves. Round, flanged and DM-35 duct transitions. Retaining angles. Net OD dimensions. Varying fuse link temps, sleeve lengths and clearances. Horizontal and vertical applications.

VFD-10-TL, VFD-10D-TL

TX, CA
24hr
5*
Min. charge 40%
3-Day
5*
Min. charge 25%
7-Day
15*
Min. charge 15%
16, 18 & 20 GA. A, or B sleeves. Round, flanged and DM-35 duct transitions. Retaining angles, Net OD dimensions. Varying fuse link temps, sleeve lengths and clearances. Horizontal and vertical applications.

VFD-10-IM

TX, CA
24hr
50
Min. charge 40%
3-Day
100
Min. charge 25%
7-Day
200
Min. charge 15%
20 GA. A, or B sleeves. Round, flanged and DM-35 duct transitions. Retaining angles. Net OD dimensions. Varying fuse link temps, sleeve lengths and clearances. Horizontal and vertical applications.

VFD-10D

TX, CA
24hr
50*
3-Day
100*
Min. charge 25%
7-Day
200*
Min. charge 15%
4000 fpm, 16, 18 & 20 GA. A or B sleeves. Round, flanged and DM-35 duct transitions. Stainless steel. Retaining angles. Net OD dimensions. Varying fuse link temps, sleeve lengths and clearances. Horizontal and vertical applications.

VFD-10D

TX, CA
24hr
-
3-Day
100*
Min. charge 25%
7-Day
200*
Min. charge 15%
4000 fpm, 16, 18 & 20 GA. A, B or C sleeves. Round, flanged and DM-35 duct transitions. Stainless steel. Retaining angles. Net OD dimensions. Varying fuse link temps, sleeve lengths and clearances. Horizontal and vertical applications.

VFD-30D

TX, CA
24hr
50*
Min. charge 40%
3-Day
100*
Min. charge 25%
7-Day
200*
Min. charge 15%
4000 fpm, 16, 18 & 20 GA. A or B sleeves. Round, flanged and DM-35 duct transitions. Stainless steel. Retaining angles. Net OD dimensions. Varying fuse link temps, sleeve lengths and clearances. Horizontal and vertical applications.

VFD-15R, VFD-35R

CA
24hr
5
Min. charge 40%
3-Day
10
Min. charge 25%
7-Day
25
Min. charge 15%
16 & 20 GA. sleeves. Varying fuse link temps, sleeve lengths and clearances. Horizontal and vertical applications.

VFD-15R-IS, VFD-35R-IS

CA
24hr
5
Min. charge 40%
3-Day
10
Min. charge 25%
7-Day
25
Min. charge 15%
20 GA. sleeves. Varying fuse link temps, sleeve lengths and clearances. Horizontal and vertical applications.

FD-125R

CA
24hr
15
Min. charge 40%
3-Day
20
Min. charge 25%
7-Day
30
Min. charge 15%
Varying fuse link temps.

FD-140 (OP), FD-150 (OP), FD-340

TX, CA
24hr
15*
Min. charge 40%
3-Day
20*
Min. charge 25%
7-Day
30*
Min. charge 15%
16, 18 & 20 GA. sleeves. Round, flanged and DM-35 duct transitions. Horizontal and vertical applications.

Smoke & Fire/Smoke Dampers

FSD-141, 142, 143, (OP), (SP)

TX, CA
24hr
15*
Min. charge 40%
3-Day
20*
Min. charge 25%
7-Day
30*
Min. charge 15%
Side plate. 16, 18 & 20 GA. sleeves. No sleeves. Round, flanged and DM-35 duct transitions. Stainless steel. Retaining angles. Net OD dimensions. Stock actuators. PI-50. Duct mounted smoke detector (3-day, maximum of 5 units or 7-day only) and loose smoke detector. Varying fuse link temps, sleeve lengths and clearances. DRS-30, RCP-1, RCP-1K, RCP-1M and RCP-1M-NL.

FSD-151, 152, (OP), (SP)

CA
24hr
15*
Min. charge 40%
3-Day
20*
Min. charge 25%
7-Day
30*
Min. charge 15%
Side plate. 16, 18 & 20 GA. sleeves. No sleeves. Round, flanged and DM-35 duct transitions. Stainless steel. Retaining angles. Net OD dimensions. Stock actuators. PI-50. Duct mounted smoke detector (3-day, maximum of 5 units or 7-day only) and loose smoke detector. Varying fuse link temps, sleeve lengths and clearances. DRS-30, RCP-1, RCP-1K, RCP-1M and RCP-1M-NL.

FSD-171 (OP), FSD-172 (OP)

TX, CA
24hr
15
Min. charge 40%
3-Day
20
Min. charge 25%
7-Day
30
Min. charge 15%
16, 18 & 20 GA. sleeves. Round, flanged and DM-35 duct transitions. Stainless steel. Stock actuators. PI-50. Duct mounted smoke detector (3-day, maximum of 5 units or 7-day only) and loose smoke detector. DRS-30, RCP-1, RCP-1K, RCP-1M and RCP-1M-NL.

FSD-341, 342, 351, 352

TX, CA
24hr
15*
Min. charge 40%
3-Day
20*
Min. charge 25%
7-Day
30*
Min. charge 15%
Side plate. 16, 18 & 20 GA. sleeves. No sleeves. Round, flanged and DM-35 duct transitions. Retaining angles. Net OD dimensions. Stock actuators. PI-50. Duct mounted smoke detector (3-day, maximum of 5 units or 7-day only) and loose smoke detector. Varying fuse link temps, sleeve lengths and clearances. DRS-30, RCP-1, RCP-1K, RCP-1M and RCP-1M-NL.

FSD-125R

CA
24hr
15
Min. charge 40%
3-Day
20
Min. charge 25%
7-Day
30
Min. charge 15%
Varying fuse link temps. Stock actuators. DRS-30, Horizontal mount, RCP-1, RCP-1K, RCP-1M and RCP-1M-NL.

SD-141, 142

TX, CA
24hr
15
Min. charge 40%
3-Day
20
Min. charge 25%
7-Day
30
Min. charge 15%
Retaining angles. Net OD dimensions. Stock actuators. PI-50. Duct mounted smoke detector (3-day, maximum of 5 units or 7-day only) and loose smoke detector. Varying sleeve lengths and clearances. DRS-30, RCP-1, RCP-1K, RCP-1M and RCP-1M-NL.

SD-151, 152

CA
24hr
15
Min. charge 40%
3-Day
20
Min. charge 25%
7-Day
30
Min. charge 15%
Retaining angles. Net OD dimensions. Stock actuators. PI-50. Duct mounted smoke detector (3-day, maximum of 5 units or 7-day only) and loose smoke detector. Varying sleeve lengths and clearances. DRS-30, RCP-1, RCP-1K, RCP-1M and RCP-1M-NL.

SD-25R

CA
24hr
15
Min. charge 40%
3-Day
20
Min. charge 25%
7-Day
30
Min. charge 15%
Stock actuators. RCP-1, RCP-1K, RCP-1M and RCP-1M-NL

Ceiling Radiation Dampers

CFD-15R

TX, CA
24hr
50
Min. charge 40%
3-Day
100
Min. charge 25%
7-Day
200
Min. charge 15%
CRB-24, WHI-20.

CFD-15R

TX, CA
24hr
25
Min. charge 40%
3-Day
50
Min. charge 25%
7-Day
100
Min. charge 15%
22 GA sleeves. VC-165, CRB-24, WHI-20. Varying sleeve lengths.

CFD-15 (No Round Transitions)

TX, CA
24hr
50
Min. charge 40%
3-Day
100
Min. charge 25%
7-Day
200
Min. charge 15%
22 GA. sleeves. Flange transition. VC-165, CRB-24, WHI-20. All plaster ground connections. Varying sleeve lengths.

CFD-15 (With Round Transitions)

TX, CA
24hr
-
3-Day
20
Min. charge 25%
7-Day
50
Min. charge 15%
22 GA. sleeves. Flange transition. VC-165, CRB-24, WHI-20. All plaster ground connections. Varying sleeve lengths.

CFD-521 (NP)

TX
24hr
50
Min. charge 40%
3-Day
100
Min. charge 25%
7-Day
200
Min. charge 15%
Round transitions (mounted or loose). VC-165, WHI-20. All plaster ground connections. Boot rails.

CFD-521-IP

TX
24hr
50
Min. charge 40%
3-Day
100
Min. charge 25%
7-Day
200
Min. charge 15%
VC-165, WHI-20. All plaster ground connections. Boot rails. Round transitions (mounted or loose).

CFD-521-90

TX
24hr
-
3-Day
100
Min. charge 25%
7-Day
200
Min. charge 15%

CFD-521-BT

TX
24hr
25
Min. charge 40%
3-Day
50
Min. charge 25%
7-Day
100
Min. charge 15%
R-8.0. VC-165. Boot rails. Does not apply to 45° option.

CFD-20

TX, CA
24hr
30
Min. charge 40%
3-Day
60
Min. charge 25%
7-Day
120
Min. charge 15%
22 GA sleeves. Round duct transitions. CRB-24, WHI-20. All plaster ground connections. Varying sleeve lengths.

Air Control Dampers

CD-10R

CA
24hr
30
Min. charge 40%
3-Day
80
Min. charge 25%
7-Day
200
Min. charge 15%
22 GA. Sleeves. Standoff. Stainless steel. Varying sleeve lengths and clearances. Locking quadrants.

CD-10

CA
24hr
30
Min. charge 40%
3-Day
60
Min. charge 25%
7-Day
120
Min. charge 15%
22 GA. Sleeves. Standoff. Locking quadrants.

CD-21R

CA
24hr
30
Min. charge 40%
3-Day
60
Min. charge 25%
7-Day
150
Min. charge 15%
Low leakage seals. Stock actuators. Stainless steel. Varying sleeve lengths. Standoff brackets.

CD-25R

CA
24hr
30
Min. charge 40%
3-Day
60
Min. charge 25%
7-Day
150
Min. charge 15%
Low leakage seals. Stock actuators. Stainless steel. Varying sleeve lengths. Locking quadrants. Standoff brackets.

CD-41, 42, 45, 46

TX, CA
24hr
15*
Min. charge 40%
3-Day
45*
Min. charge 25%
7-Day
60*
Min. charge 15%
Low leakage seals. Locking quadrants. Stock actuators. 16, 18 and 20 GA. Sleeves. Round. Flanged. DM-35 duct transitions. Stainless steel. Side plates. Net OD dimensions. Varying sleeve lengths and clearances. Standoff. Vertical blades. Stainless steel bushings. PI-50.

CD-51, 52

TX, CA
24hr
-
3-Day
20*
Min. charge 25%
7-Day
50*
Min. charge 15%
Low leakage seals. Locking quadrants. Stock actuators. 16, 18 and 20 GA. Sleeves. Round. Flanged. DM-35 duct transitions. Side plates. New OD dimensions. Varying sleeve lengths and clearances. Standoff. Vertical blades. Stainless steel bushings. PI-50.

MD-41, 42

TX, CA
24hr
15*
Min. charge 40%
3-Day
45*
Min. charge 25%
7-Day
60*
Min. charge 15%
Standoff. Locking quadrant. Net OD dimensions. No top/bottom stops. Stainless steel bushings.

Backdraft Dampers

BD-20R (catalog sizes only)

TX, CA
24hr
-
3-Day
-
7-Day
100
Min. charge 15%

BD-150, 250

TX
24hr
30*
Min. charge 40%
3-Day
60*
Min. charge 25%
7-Day
120*
Min. charge 15%
B (Discharge) or C (Intake) mounting flange. Net OD dimensions.

BD-150, 250 (with sleeves and/or Stock actuators)

TX
24hr
-
3-Day
10*
Min. charge 25%
7-Day
20*
Min. charge 15%
B (Discharge) or C (Intake) mounting flange. New OD dimensions. Varying sleeve lengths and clearances. 16, 18 and 20 GA. Stock actuators.

CBD-150, 250

TX
24hr
30*
Min. charge 40%
3-Day
60*
Min. charge 25%
7-Day
120*
Min. charge 15%
B (Discharge) or C (Intake) mounting flange. New OD dimensions. Vertical or horizontal. Airflow up mount.

CBD-150, 250 (with sleeves)

TX
24hr
-
3-Day
10*
Min. charge 25%
7-Day
20*
Min. charge 15%
B (Discharge) or C (Intake) mounting flange. New OD dimensions. Varying sleeve lengths and clearances. 16, 18 and 20 GA. Stock actuators.

BD-51

TX
24hr
10*
Min. charge 40%
3-Day
20*
Min. charge 25%
7-Day
60*
Min. charge 15%
B or C mounting flange. New OD dimensions. Varying sleeve lengths and clearances. 16, 18 and 20 GA.

Louvers

Standard paint extends the Quick Ship Program by 2 days

SFD-445/635, SFJ-445/645

CA
24hr
-
3-Day
5*
Min. charge 25%
7-Day
10*
Min. charge 15%
Integral flange frame (mechanically fastened only). Standard head and sill flashing. New OD dimensions. Clip and continuous angles. No screen. Insect screen - aluminum (18-16 mesh).

ECD-245/445/545/635
EDD-445/637
EFD-245/435/437/445/637/645
EFJ 430/437/445, EFK-430/437/445
EFJ-437-HP, EFJ-637-HP

TX
24hr
≤50 sq. ft.
Min. charge 40%
3-Day
≤175 sq. ft.
Min. charge 25%
7-Day
≤250 sq. ft.
Min. charge 15%
Integral flange frame (mechanically fastened only). Standard head and sill flashing. Net OD dimensions. Clip and continuous angles. Screen location - front/exterior. No screen. Insect screen - aluminum (18-14 mesh). Insect screen - aluminum (18-16 mesh). Bird screen - galvanized (1/2” x 19 GA). Insect screen - stainless steel (18-16 mesh). Florida Building Code construction. Custom flange (n/a for 24 hour). Stucco and glazing frame - match louver. Frame only - match louver. Filter rack. Blankoff. Burglar bars.

EFJ-937-MD, EXA-645-MD

TX
24hr
-
3-Day
-
7-Day
≤50 sq. ft.
Min. charge 15%
Integral flange frame (mechanically fastened only). Standard head and sill flashing. Net OD dimensions. Clip and continuous angles. Screen location - front/exterior. No screen. Insect screen - aluminum (18-14 mesh). Insect screen - aluminum (18-16 mesh). Bird screen - galvanized (1/2” x 19 GA). Insect screen - stainless steel (18-16 mesh). Florida Building Code construction. Custom flange (n/a for 24 hour). Stucco and glazing frame - match louver. Frame only - match louver. Filter rack. Blankoff. Burglar bars.

EFY-245/445, EFJ-245/645
EFK-637/645

TX
24hr
≤25 sq. ft.
Min. charge 40%
3-Day
≤100 sq. ft.
Min. charge 25%
7-Day
≤150 sq. ft.
Min. charge 15%
Integral flange frame (mechanically fastened only). Standard head and sill flashing. Net OD dimensions. Clip and continuous angles. Screen location - front/exterior. No screen. Insect screen - aluminum (18-14 mesh). Insect screen - aluminum (18-16 mesh). Bird screen - galvanized (1/2” x 19 GA). Insect screen - stainless steel (18-16 mesh). Florida Building Code construction. Custom flange (n/a for 24 hour). Stucco and glazing frame - match louver. Frame only - match louver. Filter rack. Blankoff. Burglar bars.

EFD-637-MD

TX
24hr
≤25 sq. ft.
Min. charge 40%
3-Day
≤50 sq. ft.
Min. charge 25%
7-Day
≤100 sq. ft.
Min. charge 15%
Integral flange frame (mechanically fastened only). Standard head and sill flashing. Net OD dimensions. Clip and continuous angles. Sleeved (n/a for 24 hour). Screen location - Front/exterior. No screen. Insect Screen - aluminum (18-14 mesh). Insect screen - aluminum (18-16 mesh). Bird screen - galvanized (1/2” x 19 GA.). Insect screen - stainless steel (18-16 mesh). Florida Building Code construction. Custom flanges (n/a for 24 hour). Stucco and glazing frame. Screen and frame - match louver. Frame only - match louver. Filter rack. Blankoff. Burglar bars.

ECD-545-MD

TX
24hr
-
3-Day
-
7-Day
≤100 sq. ft.
Min. charge 15%
Integral flange frame (mechanically fastened only). Standard head and sill flashing. Net OD dimensions. Clip and continuous angles. Sleeved. Screen location - Front/exterior. No screen. Insect Screen - aluminum (18-14 mesh). Insect screen - aluminum (18-16 mesh). Bird screen - galvanized (1/2” x 19 GA.) Insect screen - stainless steel (18-16 mesh). Custom flanges (n/a for 24 hour). Stucco and glazing frame. Screen and frame - match louver. Frame only - match louver. Filter rack. Blankoff. Burglar bars.

EEI-430, EFE-430-HP

TX
24hr
-
3-Day
≤25 sq. ft.
Min. charge 25%
7-Day
≤50 sq. ft.
Min. charge 15%
Integral flange frame (mechanically fastened only). Standard head and sill flashing. Net OD dimensions. Clip and continuous angles. Screen location - Front/exterior. No screen. Insect Screen - aluminum (18-14 mesh). Insect screen - aluminum (18-16 mesh). Bird screen - galvanized (1/2” x 19 GA.) Insect screen - stainless steel (18-16 mesh). Custom flanges (n/a for 24 hour). Stucco and glazing frame. Screen and frame - match louver. Frame only - match louver. Filter rack. Blankoff. Burglar bars.

ECD-745

TX
24hr
-
3-Day
≤25 sq. ft.
Min. charge 25%
7-Day
≤50 sq. ft.
Min. charge 15%
Standard head and sill flashing. Net OD dimensions. Clip and continuous angles. Screen location - Front/exterior. No screen. Insect Screen - aluminum (18-14 mesh). Insect screen - aluminum (18-16 mesh). Bird screen - galvanized (1/2” x 19 GA.). Insect screen - stainless steel (18-16 mesh). Custom flanges (n/a for 24 hour). Stucco and glazing frame. Screen and frame - match louver. Frame only - match louver. Filter rack. Blankoff. Burglar bars.

EBE-445, EBI-445

TX
24hr
-
3-Day
≤25 sq. ft.
Min. charge 25%
7-Day
≤50 sq. ft.
Min. charge 15%
Integral flange frame (mechanically fastened only). Standard head and sill flashing. Net OD dimensions. Clip and continuous angles. Screen location - Front/exterior. No screen. Insect Screen - aluminum (18-14 mesh). Insect screen - aluminum (18-16 mesh). Bird screen - galvanized (1/2” x 19 GA.) Insect screen - stainless steel (18-16 mesh). Custom flanges (n/a for 24 hour). Stucco and glazing frame. Screen and frame - match louver. Frame only - match louver. Filter rack. Blankoff. Burglar bars.

EOD-445/637, EOJ-445/637
EXD-437/645, EXA-645

TX
24hr
-
3-Day
≤25 sq. ft.
Min. charge 25%
7-Day
≤50 sq. ft.
Min. charge 15%
Stock actuators. Integral flange frame (mechanically fastened only). Standard head and sill flashing. Net OD dimensions. Clip and continuous angles. Jamb and blade seals. Screen location - Front/exterior. No screen. Insect screen - aluminum (18-14 mesh). Insect screen - aluminum (18-16 mesh). Bird screen - galvanized (1/2” x 19 GA.) Insect screen - stainless steel (18-16 mesh). Custom flanges (n/a for 24 hour). Stucco and glazing frame. Screen and frame - match louver. Frame only - match louver. Filter rack. Blankoff. Burglar bars.

EBV-145/445 (Catalog sizes only)

TX
24hr
-
3-Day
50
Min. charge 25%
7-Day
150
Min. charge 15%

Access Doors

HAD, CAD (Catalog sizes only)

CA, TX
24hr
10
Min. charge 40%
3-Day
25
Min. charge 25%
7-Day
100
Min. charge 15%
Standard latch quantities.

DM, DMR (Catalog sizes only)

CA, TX
24hr
-
3-Day
20
Min. charge 25%
7-Day
40
Min. charge 15%

DMHT-2300 (Catalog sizes only)

CA, TX
24hr
-
3-Day
5
Min. charge 25%
7-Day
10
Min. charge 15%
Notes
  • * Denotes single sections. 1/2 quantities are available for two sections. 1/3 quantities available for three sections.
  • Options and accessories shown in bold are only available on the 7-day program.
  • 24 Hr, 3-Day and 7-Day Quick Ship: Orders received before 12 noon (central time) will ship the next business day, 3 days or 7 days respectively. Orders received after noon (central time) will ship in 2 days, 4 days or 8 days respectively.
  • Minimum charge $40 or 40% for 24 hour, $25 or 25% for 3-day, $15 or 15% for 7-day, whichever is greater.
  • Please contact Pottorff Customer Service at 817-509-2300 for special requirements.
  • Manufacturing location indicates CA-California or TX-Texas.

Revisions: 09/26